Early detection of ischemic injury, though difficult to achieve is becoming increasingly critical to the proper utilization of new therapeutic intervention. Experts note that although Magnetic Resonance angiography provides flow information and can image the blockage structure, the method cannot characterize tissue damage. Rockland Technimed's patented Tissue Viability Imaging Agent provides the missing link and critical test in assessing the quality and function of the underlying tissue. It can differentiate between reversible or irreversible tissue injury. It provides the measurement of Oxygen Extraction Fraction/Rate which is only possible using PET/CT with radioisotopes today.
The new patented technology is based on the normal process of cellular regeneration of adenosine triphosphate with concomitant conversion of oxygen to water. Oxy-17® is formulated using a stable, non radioactive isotope of Oxygen, can be used to detect hypoxic, but still viable tissue. After Oxy-17® is absorbed by the cell and converted to water it perturbs the proton signal and creates a negative contrast on the MRI. Each injury zone has a different rate of oxygen uptake so each zone can be differentiated using MRI. Oxygen-starved hypoxic tissue consumes a larger percentage of oxygen than normal tissue while nonviable (necrotic) tissue will not take up the Oxy-17 and will not produce any water with it. It is like an early warning radar of tissue injury.

|
|
|
|

|
|
| |
Conventional ( T2 or spin-spin relaxation weighted) MRI used with this technique, can detect the difference between areas that contain water with O-17 and water with O-16, regions that are hypoxic but viable can be distinguished from regions in which cell death has occurred. Oxy-17® can cross an intact blood brain barrier, thus rendering this an ideal technique for brain imaging. Gadolinium or iron oxide based contrast agents can not cross the INTACT blood brain barrier More than 38% contrast is observed between the normal control image and an image after a bolus venous injection of the Oxy-17
Oxy-17® is formulated using a naturally occuring stable non radioactive component of air to which all living cells have been exposed and have used since the evolution of life on this planet Earth, therby assuring patient safety.
Rockland Technimed
has demonstrated that the Oxy-17® has been found to
be imaging the areas of ischemia or reperfusion like myocardial ischemia, stroke and
may be applicable in abdominal viceral tissue ischemic injury. Other potential uses for future investigation include mapping the epicenter in epilepsy, categorizing tumor oxygenation, cancer staging, and assessing the
efficacy of radiation and chemotherapy.
|
|
| |
 |
| |
|
What the press says :
|
|
Rockland Technimed Ltd.
Maratha House, 3 Larissa Court, Airmont, NY USA
Telephone: 001-(845)-426-3406, Fax -001- (845)-426-1109
Email - info@technimed.com Webmaster - webmaster@technimed.com
Copyright © 1999-2007 Rockland Technimed Ltd. All rights reserved.
|
| Oxy-17® is a registered Trade Mark of Rockland Technimed Ltd for: Oxygen-based diagnostic agents, preparations and substances for medical purposes, namely, contrast media for medical imaging for use with MRI diagnostic apparatus, and diagnostic scanning agents in the nature of contrast media for use in In-Vivo imaging. |
|